APPLE AUTOMATION AND SENSOR

Mumbai, India gst GST No.27ACRPG0717F1ZQ

  • Menics Tower Light without Pillar

Menics Tower Light without Pillar

Minimum Order Quantity : 1 Pieces

Menics Tower Light without Pillar Price & Specifications

Usage & Applications Industrial Signalling, Machine Status Indication, Automation Equipment

Rated Voltage 24V DC / 230V AC

Rated Current Max 30mA

Power Rating 2W per Module

Phase Single Phase

Operating Temperature -10A C to +50A C

Material Polycarbonate Lens, ABS Housing

Frequency 50/60Hz

Features Modular Design, High Brightness, Slim Profile, Easy Installation

Display Type LED

Conductor Copper

Cable Type 3 Core Cable

About Menics Tower Light without Pillar Detail

Menics Tower Light without pillar one stage 12/24 VDC, 110/220 AC inform while ordering in India, Mumbai, Delhi, Ahmedabad, Chennai, Kolkata, Pune, Nashik, Aurangabad, Nagpur Vapi, Silvassa, Surat, Vadodara, Rajkot, Gandhidham, Morbi, Indore, Bhopal, Faridabad, Ghaziabad, Noida, Gurgaon, Coimbatore, Bangalore, Hyderabad, Kanpur, Goa, Vishakhapatnam, Cochin, Ernakulum, Ludhiana, Chandigarh, Baddi, Dehradun, China, Korea, Taiwan, Singapore, UAE, Dubai, Malaysia, Srilanka, Bangladesh, Sourth Africa.


High Visibility Modular Design

The tower lights modular nature allows users to select up to five color indicators, providing instant clarity for machine operators. Its high-brightness LED modules ensure visibility in varied industrial environments, while the slim profile makes integration into tight spaces effortless. Flexible configuration meets evolving operational needs.


Durable Construction for Industrial Use

Manufactured with a robust polycarbonate lens and ABS housing, the Menics Tower Light resists impacts and harsh conditions found in factories. With an IP52 rating, it can withstand dust and light water sprays, making it reliable for long-term use in automation systems and industrial signals.


Simple and Efficient Installation

Featuring a base mount without a pillar and a terminal block connection, this tower light offers straightforward installation. The modular build lets users easily add or remove color modules, while the 3-core cable and copper conductor provide secure connectivity, helping reduce downtime during setup.

FAQs of Menics Tower Light without Pillar:


Q: How do I install the Menics Tower Light without a pillar?

A: Installation is straightforwardmount the base onto your equipment using the terminal block connection for secure wiring. The modular design also allows you to stack or remove color modules as needed, making expansion or maintenance effortless.

Q: What are the available color options and how can I customize the indicator?

A: You can choose from red, yellow, green, blue, and white modules. Each tower can accommodate from one to five color modules, enabling tailored status indications for diverse industrial requirements.

Q: When should I use the optional buzzer module?

A: The optional buzzer module is beneficial when visual alerts need to be reinforced with an acoustic signal. Its particularly useful in noisy production settings, ensuring operators are promptly alerted to changes in machine status.

Q: Where is the Menics Tower Light most commonly used?

A: This tower light is widely installed on machinery and automation equipment in industrial settingsincluding factories, manufacturing units, and assembly linesto provide real-time status indication and support safe operations.

Q: What benefits does the LED display type offer compared to traditional lamps?

A: The integrated LED technology provides over 50,000 hours of lamp life, offering higher energy efficiency, reduced maintenance costs, and consistent high brightness for clearer signaling compared to conventional incandescent lamps.

Q: How does the modular design improve usage and maintenance?

A: The modular architecture allows users to adjust the number of signaling layers as operational needs change, or replace individual modules independently. This streamlines repairs and upgrades without needing to substitute the entire tower unit.

More Similar Menics Tower Light without Pillar Products

Menics Tower Light

Menics Tower Light

Minimum Order Quantity : 1 Pieces

Rated Voltage : 24V AC/DC, 110V AC, 220V AC (Model Dependent)

Rated Current : 0.2A (Approx.)

Power Rating : Max 5W per module

Phase : Single Phase

Frequency : 50/60 Hz

Menics Tower Light with Pillar

Menics Tower Light with Pillar

Minimum Order Quantity : 1 Pieces

Usage & Applications : Industrial Automation, Machinery, Process Control, Safety and Warning Indication

Rated Voltage : 24V DC / 220V AC (Model Dependent)

Rated Current : < 50 mA per Module

Power Rating : 1.2W per Module

Phase : Single

Menics Tower Lamp

Menics Tower Lamp

Minimum Order Quantity : 1 Pieces

Usage & Applications : Industrial automation, machinery status indication, control panels, conveyors, safety warning

Rated Voltage : 24V DC / 230V AC

Rated Current : Max 40mA per segment

Power Rating : Maximum 2W per segment

Phase : Single Phase