4421AD1 GIC Liquid Level Monitoring Relay Price & Specifications
Usage & Applications Liquid Level Monitoring and Control in Tanks and Reservoirs
Rated Voltage 230V AC
Rated Current 5A @ 230V AC
Power Rating 2 VA
Phase Single Phase
Operating Temperature -10A C to +55A C
Material ABS Plastic Housing
Frequency 50/60 Hz
Features Automatic water pump control, Compact size, High reliability, Adjustable sensitivity, Over/Under level detection
Display Type LED Indication
Conductor Copper
Cable Type Compatible with standard control cables
Supply Ability 10 Per Day
Sample Policy Sample costs shipping and taxes has to be paid by the buyer
Sample Available Yes
Payment Terms Western Union, Cash Against Delivery (CAD), Cash on Delivery (COD), Cash Advance (CA), Cash in Advance (CID), Cheque, Days after Acceptance (DA), Delivery Point (DP), Letter of Credit at Sight (Sight L/C), Telegraphic Transfer (T/T), Paypal, Others, Letter of Credit (L/C)
Packaging Details Box
Main Export Market(s) Central America, Asia, Australia, Africa, Middle East, Western Europe, Eastern Europe, South America, North America
Main Domestic Market All India
FOB Port FOB Port
Delivery Time 1 Days
Certifications Certifications
About 4421AD1 GIC Liquid Level Monitoring Relay Detail
4421AD1 GIC Liquid Level Monitoring Relay
We are Dealer, Supplier, Distributor of 4421AD1 GIC Liquid Level Monitoring Relay and offer Price in India. Apple Automation and Sensor are Dealer, Supplier and Distributor of GIC in India, Mumbai, Delhi, Ahmedabad, Chennai, Kolkata, Pune, Nashik, Aurangabad, Nagpur Vapi, Silvassa, Surat, Vadodara, Rajkot, Gandhidham, Morbi, Indore, Bhopal, Faridabad, Ghaziabad, Noida, Gurgaon, Coimbatore, Bangalore, Hyderabad, Kanpur, Goa, Vishakhapatnam, Cochin, Ernakulam, Ludhiana, Chandigarh, Baddi, Dehradun, Nagpur, Sangli, Satara, Ichalkarnji, Solapur, Kupwad, Kolhapur, Pimpri, Chinchwad, Jalgaon, Silvassa, Surat, Baroda, Morbi.
Product Specification
Model : 4421AD1
Multiple Model No : 4411AD1, 4421AD1, 4431AD1
Brand : GIC
Option : Input, Output, Size, Weight, Dimension, Function, Usage, Accuracy, Resolution, Voltage
Warranty: 1 Year
Precise Liquid Level MonitoringDesigned for robust liquid level detection, the 4421AD1 GIC Relay brings accuracy and efficiency to tank and reservoir management. With its adjustable sensitivity and quick response time of 200 ms, it allows seamless integration into industrial automation setups, promoting operational safety and resource optimization.
Versatile and User-Friendly DesignThe compact dimensions and DIN rail mounting of the 4421AD1 make installation effortless, requiring little panel space. Its LED indication offers real-time status feedback, while the ABS plastic housing ensures durability in diverse environments. Ideal for use by dealers, exporters, manufacturers, and more across India.
FAQ's of 4421AD1 GIC Liquid Level Monitoring Relay:
Q: How does the 4421AD1 GIC Liquid Level Monitoring Relay operate?
A: The relay uses electrode/probe input to detect liquid levels within tanks or reservoirs. When the fluid reaches a set level, the relay triggers its SPDT output, enabling actions like automatic water pump control. The sensitivity setting can be adjusted for different liquids within a 5 k to 100 k range.
Q: What are the main benefits of using the 4421AD1 Liquid Level Relay in industrial applications?
A: Key benefits include precise liquid level detection, fast response ( 200 ms), straightforward installation with DIN rail mounting, adjustable sensitivity for various liquid types, and automatic control of pumps. Additionally, its compact size saves panel space, and LED indication assists in quick status checks.
Q: Where should the 4421AD1 Relay be installed for optimal performance?
A: Install the relay on a DIN rail inside electrical control panels, keeping it away from sources of excessive moisture or dust. The IP20 protection is suitable for most indoor industrial settings, and its compact dimensions (22.5 mm x 75 mm x 110 mm) make it easy to fit into standard enclosures.
Q: What cables and conductors are compatible with this relay?
A: The 4421AD1 is compatible with standard control cables and requires copper conductors for optimal electrical performance. Proper cable sizing and secure connections ensure reliable operation and resistance to electrical faults.
Q: When is it necessary to adjust the sensitivity of the relay?
A: Sensitivity should be adjusted when monitoring different liquids or when specific response thresholds are required. For high-resistivity liquids, a higher sensitivity setting (up to 100 k) may be needed, whereas lower-resistivity fluids may require a lower setting.
Q: What is the process for wiring and commissioning the relay?
A: Begin by mounting the relay on the DIN rail and connecting electrode probes to the input terminals using copper conductors. Make the necessary connections to the relay output (SPDT) and supply 230V AC rated voltage. Adjust the sensitivity as required and verify the LED for status indication before commissioning the system.